SC Speed Sensor
Quick Overview
- Non-contact, solid state device.
- Tight magnetic tolerance around zero Gauss level provides 50% duty cycle.
- Reads speeds 0 to 100 kHz.
- Digital output signal
- 4 to 24 VDC operation range
- Current sinking output
- 20ma continuous operation
- Reverse polarity protection
- Temperature compensated
- Operates from -40°C to 125°C
- Rugged thermoplastic housing
- Photos
-
- Mechanical Drawing Preview
Price:
Product Description
Part Number Configuration Guide
Download
Product Specifications
- Magnetic
-
Characteristic Symbol Limits Min. Typ. Max. Units Operating Point BOP 32 95 Gauss Release Point BRP -95 -20 Gauss Hysteresis BHYS 30 52 Gauss Maximum Field Exposure BMAX Gauss Active Element Depth DP 0.02 Inch - Electrical
-
Characteristic Symbol Test Condition LimitsMin. Typ. Max. Units Supply Voltage VCC Operating 4.5 24 VDC Supply Current IS VCC - 4.5V; Output Open 4.7 8.0 mA Output Current IOUT VCC = 4.5V; Output Open 20 mA Output Saturation Voltage VOUT(SAT) B > BOP; IOUT = 20mA 150 400 mV Output Leakage Current IOFF B < BRP; VOUT = 24V 4.7 10 uA Rise/Fall Time tr / tf RL = 1.2k; CL < 33pF 2 us - Output Definition
-
Recommended Pull-Up Resistor Values Current, ISINK 5V Supply 12V Supply 24V Supply 1.2 mA 4.3K 10.0K 20.0K 2.5 mA 2.0K 4.7K 10.0K 5.0 mA 1.0K 2.4K 4.7K 10.0 mA 510Ω 1.2K 2.4K Output channels require customer supplied pull-up resistors unless internal pull-up option is selected.
- Wiring & Connection
-
Standard Wiring Code Flying Leads Output Blue Gnd Black +VCC Red Wiring Option Connector Options